Human anti-cardiolipin antibody IgG,ACA-IgG ELISA Kit, 96T
Zoom image

Human anti-cardiolipin antibody IgG,ACA-IgG ELISA Kit, 96T

Supplier: TSZELISA
In stock (1000 items available)
  • $749.00
Market price: $899.00, you save $150.00
  • 17% less
Qty:  
  • CAT. NO.
    HU9463

Human Anti-cardiolipin Antibody IgG, ACA-IgG ELISA Kit, 96T


Purpose

This kit is used for the determination the existence of Human Anti-cardiolipin Antibody IgG (ACA-IgG) in human serum, plasma, cell culture supernatants, and other biological fluids.

Principle of the assay

The kit assays human ACA-IgG in the samples by the method of purified antigen pre-coated enzyme-labeled SPA ELISA. The solid-phase antigen is prepared by purified human antigen which is pre-coated onto a microplate. After loading of samples, the ACA-IgG in the controls or samples bind with the coated antigen. Then the Staphylococcal protein A (SPA)-enzyme immunoglobulin conjugates has been added into wells. After washing to remove any unbound reagent, the tetramethylbenzidine (TMB) substrate is added. TMB substrate produces blue color when catalyzing by the HRP enzyme. After reaching the desired color intensity, the reaction is terminated by addition of an acidic Stop solution which changes the solution color from blue to yellow. Determining the absorbance (OD Value) at wave length 450 nm by the microwell reader, and the existence of ACA-IgG can be calculated according to OD from positive or negative controls.

Calculation

1.       Average the duplicate readings for each control and sample and subtract the average of blank well (1 x sample buffer only).

2.       Determine P/N value: P/N= ODsample / ODnegative. If ODnegative is less than 0.1, please use 0.1 as the value. ODpositive or ODnegative is the OD from positive or negative control.

3.       If P/N ≥ 2.1, the testing sample is ACA-IgG positive; if P/N< 2.1, the testing sample is ACA-IgG negative.

4.       The normal range of ODnegative should be less than 0.21, and ODpositive should be more than 0.40, otherwise the experiment may have big errors and maybe need repeating.

5.       If the ODsample is more than 2.5 or less than 0.1, it is out of the optimal test range. Dilution or concentration of sample may be necessary for accuracy.

Kit Performance

1.    Sample from healthy people should be negative, e.g. P/N < 2.1.

2.  Specificity: simultaneous detection of recombinant or natural human ACA-IgG without cross-reaction with other cytokines.

3.   Repeatability: both inter-assay and intra-assay were less than 10 %.


*Lead time of this kit is 1-2 weeks. Shipped by FedEx air. 
*Storage: 2 - 8 C. Shelf Time: 6 months.
*Kit Experimental Time:< 2 hs

>>Trial pricing is available for first time use for certain customers, contact us to see if you are qualified.
>>>Need manual or more information of this products Email us or Call us (1-866-897-4664)

Important note: Products are intended for laboratory or manufacture use and are not to be used for diagnosis or any other purpose, which include but are not limited to, unauthorized commercial uses, ex vivo or in vivo therapeutic uses. Not for Human or Animal Consumption.

  • Manufacturer
    TSZELISA