Human anti-hepatitis C virus antibody, anti-HCV ELISA Kit, 96T
Purpose
This kit is used for the
determination the existence of Human Anti-hepatitis C Virus Antibody (anti-HCV)
in human
serum,
plasma,
cell culture supernatants,
and other biological fluids.
Principle of the assay
The kit assays human
anti-HCV
in the samples by the method of purified HCV antigen pre-coated enzyme-labeled
SPA ELISA. The solid-phase antigen is prepared by purified human
HCV antigen
which is pre-coated onto a microplate. After loading of samples, the
anti-HCV in the controls or
samples bind with the coated antigen. Then the
Staphylococcal
protein A (SPA)-enzyme immunoglobulin conjugates has been added into wells.
After washing to remove any unbound reagent, the tetramethylbenzidine (TMB)
substrate is added. TMB substrate produces blue color when catalyzing by the HRP
enzyme. After reaching the desired color intensity, the reaction is terminated
by addition of an acidic Stop solution which changes the solution color from
blue to yellow. Determining the absorbance (OD Value) at wave length 450 nm by
the microwell reader, and the existence of
anti-HCV
can be
calculated according to OD from positive or negative controls.
Calculation
1. Average the
duplicate readings for each control and sample and subtract the
average of blank well (1 x sample buffer only).
2. Determine
P/N value: P/N= ODsample / (ODpositive X 10 % + ODnegative).
If ODpositive is more than 2.5, please use 2.5 as the value. ODpositive
or ODnegative is the OD450 from positive or negative
control.
3. If P/N ≥
1.0, the testing sample is anti-HCV positive; if P/N< 1.0, the testing sample is
anti-HCV negative.
4. The normal
range of ODnegative should be less than 0.05, and ODpositive
should be more than 0.60, otherwise the experiment may have big errors and
maybe need repeating.
5. If the ODsample
is more than 2.5 or less than 0.1, it is out of the
optimal
test range. Dilution or concentration of sample may be necessary for accuracy.
Kit Performance
1.
Sample from healthy
people should be negative, e.g. P/N < 1.0.
2.
Specificity: simultaneous detection of recombinant or natural human
anti-HCV
without cross-reaction with other cytokines.
3.
Repeatability: both
inter-assay and intra-assay were less than 10 %.
*Lead time of this kit is 1-2 weeks. Shipped by
FedEx air.
*Storage: 2 - 8 C. Shelf Time: 6 months.
*Kit Experimental Time:< 2 hs
>>Trial pricing is available for first time use for certain customers,
contact us to see if you are
qualified.
>>>Need manual or more information of this products
Email us or
Call us (1-866-897-4664)
Important note:
Products are intended for laboratory or
manufacture use and are not to be used for diagnosis or any other purpose, which
include but are not limited to, unauthorized commercial uses, ex vivo or in
vivo therapeutic uses. Not for Human or Animal Consumption.